(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Please note that the MISUMI Pune office and warehouse will be closed on November 20th due to the state election.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

OMRON Alarms/Buzzers

Alarms/Buzzers products in the Electrical & Controls category from OMRON. The product can be selected based on many product specifications such as Volume, Product Type, Rated Voltage, Shape, Sound. OMRON offers products around 4 items and the product specifications can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • Others

4 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Buzzer (round body type φ 16) M2BJ

    Buzzer (round body type φ 16) M2BJ

    OMRON

    [Features]
    · A round body type with a length of 22 mm. Part of the ø16 series.
    · Available as a standard volume type (fixed 80 horns) or as a high volume type (variable 70 to 95 horns). Can produce both intermittent and continuous sound output.

    • Volume Discount
    Volume(dB) Product Type Rated Voltage(V) Shape Sound Types of sound Volume adjustment Terminal shape Dimension width(mm) Protection function (IP/drip-proof, etc.) Representative Standard Dimension length(mm) Dimension thickness(mm)
    70–95 ~ 80 - Other Silique type Continuous / Intermittent Peak / Boost Available / NA Solder terminal 24 ~ 26 Available - 18 ~ 20 28.5
    From: ₹ 1,366.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Heater Disconnection Detector K2CU

    Heater Disconnection Detector K2CU

    OMRON

    A K2CU heater burnout alarm.

    [Features]
    · Detects burnouts from small to large capacity heaters.
    · Detects heater burnout in molding and packing machinery, etc., and then outputs an alarm.
    · Boasts a high level of detection accuracy, enabling detection of single burned out wires, even when using multiple heaters.
    · Can be used with a wide range of heaters; from small to large capacity types.
    · A single K2CU-F large capacity integrated CT unit can be used for both single and triple-phase heaters.
    · The compensation function for fluctuations in voltage
    · means that false alarms will not occur due to fluctuations in heater current caused by fluctuations in the voltage from the power supply, ensuring that alarms only occur when applicable.

    • Volume Discount
    Volume(dB) Product Type Rated Voltage(V) Shape Sound Types of sound Volume adjustment Terminal shape Dimension width(mm) Protection function (IP/drip-proof, etc.) Representative Standard Dimension length(mm) Dimension thickness(mm)
    - - AC100V / Other Silique type - - - Screw terminal / Other 72 ~ 90 - - 60 89 ~ 95
    From: ₹ 4,841.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Leakage Fire Alarm - AGD

    Leakage Fire Alarm - AGD

    OMRON

    An AGD electrical leakage fire alarm.

    [Features]
    · An updated version of a long-selling product with a 30-year track record.
    · The basic functions are maintained but with greater compactness.
    · The surface type maintains the same mounting dimensions but has been more compact. The square bodied embedded type has approximately half the volume ratio as previous models (excluding the AGD-U2).
    · The built-in digital filter reduces the effects of high-frequency noise, allowing more precise monitoring of electrical leakage.
    · The output contact configuration is 1c+1a × the number of monitoring circuits. This enables remote monitoring via external signal contacts, and an alarm output for each monitoring circuit.
    · Even the square bodied embedded types come equipped with built-in buzzers (excluding the AGD-U2).
    · Can also output an alarm to any external buzzer.
    · All updated products are available with either automatic or manual recovery AGD-N5, AGD-NY5, and AGD-N52).

    Volume(dB) Product Type Rated Voltage(V) Shape Sound Types of sound Volume adjustment Terminal shape Dimension width(mm) Protection function (IP/drip-proof, etc.) Representative Standard Dimension length(mm) Dimension thickness(mm)
    70 Alarm / Buzzer Unit / Other Other Silique type / Other - - - Screw terminal 205 - - 136 153
    From: ₹ 7,768.22
    Days to Ship: 5 Day(s)
    day to ship 5 Day(s)
  • You can add up to 6 items per a category to the compare list.

    Leakage Fire Alarm - AGD Option

    Leakage Fire Alarm - AGD Option

    OMRON

    [Features]Plain name plate units for Earth Leakage / Fire Alarm AGD-U2.

    Volume(dB) Product Type Rated Voltage(V) Shape Sound Types of sound Volume adjustment Terminal shape Dimension width(mm) Protection function (IP/drip-proof, etc.) Representative Standard Dimension length(mm) Dimension thickness(mm)
    - - - - - - - - - - - - -
    From: ₹ 1,075.00
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
From
Days to Ship
Volume(dB)
Product Type
Rated Voltage(V)
Shape
Sound
Types of sound
Volume adjustment
Terminal shape
Dimension width(mm)
Protection function (IP/drip-proof, etc.)
Representative Standard
Dimension length(mm)
Dimension thickness(mm)

You can add up to 6 items per a category to the compare list.

Buzzer (round body type φ 16) M2BJ

    You can add up to 6 items per a category to the compare list.

    Heater Disconnection Detector K2CU

      You can add up to 6 items per a category to the compare list.

      Leakage Fire Alarm - AGD

        You can add up to 6 items per a category to the compare list.

        Leakage Fire Alarm - AGD Option
          Brand

          OMRON

          OMRON

          OMRON

          OMRON

          Product Series

          Buzzer (round body type φ 16) M2BJ

          Heater Disconnection Detector K2CU

          Leakage Fire Alarm - AGD

          Leakage Fire Alarm - AGD Option

          From

          ₹ 1,366.00-

          ₹ 4,841.00-

          ₹ 7,768.22-

          ₹ 1,075.00

          Days to Ship Same day or more Same day or more 5 Day(s) 5 Day(s) or more
          Volume(dB)70–95 ~ 80-70-
          Product Type--Alarm / Buzzer Unit / Other-
          Rated Voltage(V)OtherAC100V / OtherOther-
          ShapeSilique typeSilique typeSilique type / Other-
          SoundContinuous / Intermittent---
          Types of soundPeak / Boost---
          Volume adjustmentAvailable / NA---
          Terminal shapeSolder terminalScrew terminal / OtherScrew terminal-
          Dimension width(mm)24 ~ 2672 ~ 90205-
          Protection function (IP/drip-proof, etc.)Available---
          Representative Standard----
          Dimension length(mm)18 ~ 2060136-
          Dimension thickness(mm)28.589 ~ 95153-

          Loading...

          1. 1

          Related Categories to Alarms/Buzzers

          FAQ Alarms/Buzzers

          Question: How do buzzers function in electrical circuits?
          Answer: Electromagnetic buzzers use an electromagnetic coil to generate a magnetic field. This field attracts a movable diaphragm, causing mechanical vibrations. As the diaphragm moves back and forth, it produces sound waves, resulting in the audible buzzing or beeping sound. Connected to an electrical circuit, the buzzer is activated when current flows through the coil. It's important to note that there are different types of buzzers, including electromagnetic, piezoelectric, and magnetic-transducer buzzers. Each type operates on different principles
          Question: What are the typical uses of buzzers in various industries?
          Answer: Buzzers are widely used in various industries for signaling and alerting. Here are some typical uses of buzzers in different industries such as:
          1. Automotive industries: In vehicles, buzzers are employed for warning signals, such as seatbelt reminders, and low fuel indicators.
          2. Medical Industries: Medical devices use buzzers for alarms and notifications, such as indicating the end of a medical procedure or alerting healthcare professionals to specific conditions.
          3. Industrial Automation: Buzzers are used in manufacturing and industrial settings to signal the completion of processes, indicate faults, or alert operators to specific events.
          4. Security Systems Industries: Alarm systems and security devices use buzzers to produce loud alerts in the event of a breach, fire, or other security concerns.
          Question: What differentiates piezo buzzers from electromagnetic buzzers?
          Answer: This table summarizes the key differences between piezo buzzers and electromagnetic buzzers in terms of their operating principles, mechanisms, sound frequency ranges, efficiency, size, and common applications.
          Feature Piezo Buzzers Electromagnetic Buzzers
          Operating Principle Crystal deformation Diaphragm driven by electromagnet
          Mechanism Crystal vibrations directly produce sound Diaphragm or armature physically moves to create sound
          Sound Frequency Range Narrow, often in ultrasonic or audible range Broader range, capable of various frequencies
          Efficiency High efficiency, fast response time Variable efficiency, may have slower response time
          Size and Weight Generally smaller and lighter Tends to be larger and heavier
          Applications Compact designs, low power, high-frequency Various applications, broader frequency requirements
          Question: What factors determine the loudness of a buzzer?
          Answer: 1. Power Input: Higher electrical power results in increased loudness.
          2. Design and Construction: Physical characteristics impact efficiency.
          3. Resonance Frequency: Operating at resonant frequency maximizes loudness.
          4. Voltage and Current: Increased levels within limits enhance sound output.
          5. Environmental Conditions: Surrounding factors influence perceived loudness.
          6. Transducer Efficiency: Efficient transducers produce more sound.
          7. Sound Output Mechanism: Different mechanisms impact loudness.
          8. Duty Cycle: Continuous operation may enhance perceived loudness.
          9. Frequency Range: Some frequencies are more noticeable or louder than others.
          Question: Can buzzers be considered a form of sound energy?
          Answer: Yes, buzzers can be considered a form of sound energy. Sound energy is a type of mechanical wave that propagates through a medium, such as air, water, or solids. When a buzzer is activated, it typically produces vibrations that create compressions and rarefactions in the surrounding air, generating sound waves. These sound waves carry energy in the form of vibrations, and when they reach our ears, they are perceived as sound.
          Question: How do you integrate a buzzer into a security system?
          Answer: Incorporate a buzzer into a security system by linking it to a controller, such as Arduino or Raspberry Pi. Ensure proper power alignment, connect to a digital output pin, and code the buzzer to respond to security events like unauthorized access detected by sensors.Thoroughly test and calibrate the system, considering backup power.
          Question: How do you choose the appropriate buzzer size and sound level for different environments?
          Answer: Select a buzzer size based on space constraints and application requirements. For quiet environments, opt for smaller, less powerful buzzers to minimize disturbance. In noisy settings, choose larger buzzers with higher sound levels for better audibility. Consider dB ratings to match ambient noise levels; quieter environments need lower dB, while louder surroundings require higher dB ratings. Always test in the specific environment to ensure the chosen buzzer meets the desired sound level without being excessively disruptive or inadequate for the given conditions.
          Question: What are the main considerations when connecting a buzzer to a digital circuit, such as an Arduino or Raspberry Pi?
          Answer: When buzzing with digital circuits, remember these key points:
          1. Buzzer type: Choose between active (amplified, needs only digital signal) or passive (requires driver circuit).
          2. Voltage and current: Match buzzer specs to your board's capabilities (e.g., 5V for Arduino). Calculate current draw and ensure sufficient power supply.
          3. Driving the buzzer: Use a transistor or driver IC for passive buzzers or high current needs. Connect active buzzer directly to a digital pin.
          4. Pulse frequency: Control sound pitch and pattern by varying the frequency of the digital signal driving the buzzer (typically 200Hz to 5kHz).
          5. Protection: Add a flyback diode across the buzzer to absorb reverse voltage spikes generated when switching it off.
          X
          whatsapp-qr whatsapp-icon