(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:30 15/12/2024 to 3:30 (IST) 16/12/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

CKD Solenoid Valves(Number of Ports:2-Port Valve)

CKD offers products Solenoid Valves specified by Number of Ports 2-Port Valve from Automation Components product category. There are a total of 6 items. Search and select detailed specifications of parts for your machine with free CAD downloads. CKD products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • Others

6 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Direct-Acting 2-Port Solenoid Valve Unit for Compressed Air, Just Fit Valve FAB Series

    Direct-Acting 2-Port Solenoid Valve Unit for Compressed Air, Just Fit Valve FAB Series

    CKD

    Direct acting 2-port solenoid valve for compressed air.
    [Features]
    ·NC (open when energized) type, NO (closed when energized) type.
    ·Connection port diameter: M5, Rc1/8 to Rc1/2.
    [Application]
    ·Ideal for controlling compressed air.

    CAD :
    2D
    Number of Ports Application Switching Type Voltage Number of Solenoids Mounting Orientation Pipe Port Type Specifications Status at Power Off Plumbing Thread Nominal Plumbing Applicable Cylinder Dia.(Ø) Type Driving Type Connecting Tube Diameter Pressure Rating(MPa) Seal Type CV Value Pilot Air Supply
    2-Port Valve Single Use 2-Position Normally Closed DC24V / AC100V / AC200V Single Direct M / Rc (R) Standard / Lubrication Free Self-Recovery (Spring Return) 1/2 ~ M5 Direct Plumbing - Solenoid Valves Linear Motion Poppet - - Soft Seal - -
    From: ₹ 2,848.62
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Pilot-Operated, 2-Ports Valve, Small Size Air Flow Valve EXA Series

    Pilot-Operated, 2-Ports Valve, Small Size Air Flow Valve EXA Series

    CKD

    A compact pilot-operated solenoid valve for compressed air control. It is ideal for air blow applications and contributes to the environmental friendliness of equipment and systems.
    [Features]
    ·Equipped with an energy saving actuator with the power consumption of 0.6 W, and can be directly driven by a PC.
    ・ A large flow rate is controlled by pilot-operated diaphragm drive.
    ・ Downsizing due to large flow rate compatible diaphragm and built-in fitting, weight reduction due to resin body.
    ·Supports the integration of equipment as it can be mounted on a manifold and air unit CXU.
    [Application]
    ·Ideal for dental equipment, testings, and jigs.

    CAD :
    2D / 3D
    Number of Ports Application Switching Type Voltage Number of Solenoids Mounting Orientation Pipe Port Type Specifications Status at Power Off Plumbing Thread Nominal Plumbing Applicable Cylinder Dia.(Ø) Type Driving Type Connecting Tube Diameter Pressure Rating(MPa) Seal Type CV Value Pilot Air Supply
    2-Port Valve Single Use 2-Position Normally Closed DC12V / DC24V / AC100V Single Direct One-Touch Plumbing Standard Self-Recovery (Spring Return) - Direct Plumbing - Solenoid Valves - Ø6 / Ø8 / Ø10 / Ø12 - Standard - -
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Pulse Jet Control Pilot-Operated Type 2 Port Valve PD3/PDV3 Series

    Pulse Jet Control Pilot-Operated Type 2 Port Valve PD3/PDV3 Series

    CKD

    - Pulse Jet Control Pilot-Operated Type 2 Port Valve PD3/PDV3 Series from CKD.
    - High durability: Urethane diaphragm realizes high durability by adopting a spring-less wear resistant structure.
    - Maintainability: Integrated urethane diaphragm is easy to replace.
    - Operation method: Air operated (PD3 type) and With solenoid valve (PDV3)
    - Working fluid is Air (no corrosive gas).
    - Port size can be selected into 4 sizes, 20A, 25A, 40A, or 40A-RC.

    CAD :
    2D / 3D
    Number of Ports Application Switching Type Voltage Number of Solenoids Mounting Orientation Pipe Port Type Specifications Status at Power Off Plumbing Thread Nominal Plumbing Applicable Cylinder Dia.(Ø) Type Driving Type Connecting Tube Diameter Pressure Rating(MPa) Seal Type CV Value Pilot Air Supply
    2-Port Valve Single Use 2-Position Normally Closed DC24V / AC200V Single Direct Rc (R) Standard / Lubrication Free Self-Recovery (Pressure Differential Return) 1 ~ 3/4 Direct Plumbing - Solenoid Valves Pilot Type Poppet - - Soft Seal 11 ~ 45 External
    From: ₹ 8,310.40
    Days to Ship: 7 Day(s) or more
    day to ship 7 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Microzole Single Unit Pilot-Operated 2/3/5 Port Valve P/M/B Series

    Microzole Single Unit Pilot-Operated 2/3/5 Port Valve P/M/B Series

    CKD

    A wide-use series from working pressure 1.0MPa to low vacuum. A small solenoid valve with a 15 mm width and a wide range of options. Note: CAD data of this series is being revised. Please wait till the corrections are done.

    CAD :
    2D
    Number of Ports Application Switching Type Voltage Number of Solenoids Mounting Orientation Pipe Port Type Specifications Status at Power Off Plumbing Thread Nominal Plumbing Applicable Cylinder Dia.(Ø) Type Driving Type Connecting Tube Diameter Pressure Rating(MPa) Seal Type CV Value Pilot Air Supply
    2-Port Valve Single Use 2-Position Normally Closed DC12V / DC24V / AC100V / AC110V / AC200V / AC220V Single Direct M Standard / Lubrication Free / No Copper, fluoropolymer Type Material Self-Recovery (Spring Return) M5 Direct Plumbing 6 to 16 Solenoid Valves Pilot Type Poppet - - Soft Seal - -
    Days to Ship: 11 Day(s) or more
    day to ship 11 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Pilot-kick type 2 port electromagnetic valve PKA series for air

    Pilot-kick type 2 port electromagnetic valve PKA series for air

    CKD

    2 port solenoid valve employing pilot kick system. Series provided respectively for compressed air, water and steam. Can operate from differential pressure 0 as it uses a pilot kick system.
    Note: CAD data of this series is being revised. Please wait till the corrections are done.

    CAD :
    2D / 3D
    Number of Ports Application Switching Type Voltage Number of Solenoids Mounting Orientation Pipe Port Type Specifications Status at Power Off Plumbing Thread Nominal Plumbing Applicable Cylinder Dia.(Ø) Type Driving Type Connecting Tube Diameter Pressure Rating(MPa) Seal Type CV Value Pilot Air Supply
    2-Port Valve Single Use 2-Position Normally Closed AC200V Single Direct Rc (R) Standard Self-Recovery (Spring Return) 3/4 Direct Plumbing - Solenoid Valves Pilot Type Poppet - - Soft Seal - -
    From: ₹ 16,970.13
    Days to Ship: 8 Day(s) or more
    day to ship 8 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Pilot Type 2 Port Valve Compact Air Blow Valve EXA-FP2 Series for Food Manufacturing Processes

    Pilot Type 2 Port Valve Compact Air Blow Valve EXA-FP2 Series for Food Manufacturing Processes

    CKD

    Supports food manufacturing.
    [Features]
    Food-grade lubricant (NSF H1) is used for sliding parts in flow path.
    The flow path portion uses material which conforms to the Food Sanitation Act of Japan (resin rubber).

    Number of Ports Application Switching Type Voltage Number of Solenoids Mounting Orientation Pipe Port Type Specifications Status at Power Off Plumbing Thread Nominal Plumbing Applicable Cylinder Dia.(Ø) Type Driving Type Connecting Tube Diameter Pressure Rating(MPa) Seal Type CV Value Pilot Air Supply
    2-Port Valve Single Use 2-Position Normally Closed - Single Direct One-Touch Plumbing Standard Self-Recovery (Spring Return) - Direct Plumbing - Solenoid Valves - - - Standard - -
    Days to Ship: 13 Day(s) or more
    day to ship 13 Day(s) or more
Brand
Product Series
CAD
From
Days to Ship
Number of Ports
Application
Switching Type
Voltage
Number of Solenoids
Mounting Orientation
Pipe Port Type
Specifications
Status at Power Off
Plumbing Thread Nominal
Plumbing
Applicable Cylinder Dia.(Ø)
Type
Driving Type
Connecting Tube Diameter
Pressure Rating(MPa)
Seal Type
CV Value
Pilot Air Supply

You can add up to 6 items per a category to the compare list.

Direct-Acting 2-Port Solenoid Valve Unit for Compressed Air, Just Fit Valve FAB Series

    You can add up to 6 items per a category to the compare list.

    Pilot-Operated, 2-Ports Valve, Small Size Air Flow Valve EXA Series

      You can add up to 6 items per a category to the compare list.

      Pulse Jet Control Pilot-Operated Type 2 Port Valve PD3/PDV3 Series

        You can add up to 6 items per a category to the compare list.

        Microzole Single Unit Pilot-Operated 2/3/5 Port Valve P/M/B Series

          You can add up to 6 items per a category to the compare list.

          Pilot-kick type 2 port electromagnetic valve PKA series for air

            You can add up to 6 items per a category to the compare list.

            Pilot Type 2 Port Valve Compact Air Blow Valve EXA-FP2 Series for Food Manufacturing Processes
              Brand

              CKD

              CKD

              CKD

              CKD

              CKD

              CKD

              Product Series

              Direct-Acting 2-Port Solenoid Valve Unit for Compressed Air, Just Fit Valve FAB Series

              Pilot-Operated, 2-Ports Valve, Small Size Air Flow Valve EXA Series

              Pulse Jet Control Pilot-Operated Type 2 Port Valve PD3/PDV3 Series

              Microzole Single Unit Pilot-Operated 2/3/5 Port Valve P/M/B Series

              Pilot-kick type 2 port electromagnetic valve PKA series for air

              Pilot Type 2 Port Valve Compact Air Blow Valve EXA-FP2 Series for Food Manufacturing Processes

              CAD
              • 2D
              • 2D / 3D
              • 2D / 3D
              • 2D
              • 2D / 3D
              From

              ₹ 2,848.62-

              -

              ₹ 8,310.40-

              -

              ₹ 16,970.13

              -
              Days to Ship 5 Day(s) or more 5 Day(s) or more 7 Day(s) or more 11 Day(s) or more 8 Day(s) or more 13 Day(s) or more
              Number of Ports2-Port Valve2-Port Valve2-Port Valve2-Port Valve2-Port Valve2-Port Valve
              ApplicationSingle UseSingle UseSingle UseSingle UseSingle UseSingle Use
              Switching Type2-Position Normally Closed2-Position Normally Closed2-Position Normally Closed2-Position Normally Closed2-Position Normally Closed2-Position Normally Closed
              VoltageDC24V / AC100V / AC200VDC12V / DC24V / AC100VDC24V / AC200VDC12V / DC24V / AC100V / AC110V / AC200V / AC220VAC200V-
              Number of SolenoidsSingleSingleSingleSingleSingleSingle
              Mounting OrientationDirectDirectDirectDirectDirectDirect
              Pipe Port TypeM / Rc (R)One-Touch PlumbingRc (R)MRc (R)One-Touch Plumbing
              SpecificationsStandard / Lubrication FreeStandardStandard / Lubrication FreeStandard / Lubrication Free / No Copper, fluoropolymer Type MaterialStandardStandard
              Status at Power OffSelf-Recovery (Spring Return)Self-Recovery (Spring Return)Self-Recovery (Pressure Differential Return)Self-Recovery (Spring Return)Self-Recovery (Spring Return)Self-Recovery (Spring Return)
              Plumbing Thread Nominal1/2 ~ M5-1 ~ 3/4M53/4-
              PlumbingDirect PlumbingDirect PlumbingDirect PlumbingDirect PlumbingDirect PlumbingDirect Plumbing
              Applicable Cylinder Dia.(Ø)---6 to 16--
              TypeSolenoid ValvesSolenoid ValvesSolenoid ValvesSolenoid ValvesSolenoid ValvesSolenoid Valves
              Driving TypeLinear Motion Poppet-Pilot Type PoppetPilot Type PoppetPilot Type Poppet-
              Connecting Tube Diameter-Ø6 / Ø8 / Ø10 / Ø12----
              Pressure Rating(MPa)------
              Seal TypeSoft SealStandardSoft SealSoft SealSoft SealStandard
              CV Value--11 ~ 45---
              Pilot Air Supply--External---

              Loading...

              1. 1

              Related Categories to Solenoid Valves

              FAQ Solenoid Valves

              Question: How do solenoid valves work? How does a solenoid valve control flow?
              Answer: Solenoid valves are electromechanical devices used to control the flow of fluids or gases in a system. They work based on the principle of electromagnetism. The valve consists of a coil (solenoid) and a plunger inside it.
              When an electric current passes through the coil, it creates a magnetic field, which attracts the plunger to move. This movement of the plunger opens or closes the valve's passage, allowing or blocking the flow of fluid or gas through the valve.
              By controlling the electric current to the coil, we can control the position of the plunger and, consequently, regulate the flow of the fluid or gas passing through the valve.
              Question: What are the different types of solenoid valves?
              Answer: There are several types of solenoid valves based on their design and applications. The main types include:
              2-way solenoid valves: These have one inlet and one outlet and are used to start or stop the flow of fluid or gas.
              3-way solenoid valves: These have one inlet and two outlets (or vice versa). They can divert the flow between two different paths or mix two different fluids.
              4-way solenoid valves: These have two inlets and two outlets and are commonly used in applications like directional control of pneumatic cylinders.
              Direct-acting solenoid valves: These valves use the force of the solenoid to directly open and close the valve.
              Pilot-operated solenoid valves: These use a smaller solenoid to control the flow of a larger valve, allowing them to handle higher pressures and flow rates.
              Question: What are the applications of solenoid valves?
              Answer: Solenoid valves are used in various applications across industries due to their ability to control fluid and gas flow efficiently. Some common applications include:
              Controlling water flow in irrigation systems and plumbing fixtures.
              Regulating air and gas flow in pneumatic systems and HVAC systems.
              Automation and control of industrial processes in factory automation.
              Medical equipment, such as in blood analyzers and dental instruments.
              Dispensing and vending machines for liquids and gases.
              Automotive applications, like fuel and air control in engines.
              Question: How to select the right solenoid valve for my application?
              Answer: To select the right solenoid valve for your application, consider the following factors:
              Valve Type: Choose the appropriate valve type (2-way, 3-way, etc.) based on your flow control requirements.
              Fluid or Gas Compatibility: Ensure the solenoid valve is compatible with the fluid or gas used in your system.
              Flow Rate and Pressure: Determine the required flow rate and operating pressure to select a valve that can handle the expected conditions.
              Voltage and Power: Check the voltage and power supply available in your system to match it with the solenoid valve's requirements.
              Environmental Conditions: Consider factors like temperature, humidity, and surrounding conditions to ensure the valve can withstand the environment.
              Response Time: Evaluate the response time needed for your application, as it impacts the speed of valve operation.
              X
              whatsapp-qr whatsapp-icon