(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Earth Leakage Breakers (Low Capacity)(Representative Standard:PSE)

Earth Leakage Circuit Breakers (ELCB), also known as an earth leakage switch or earth leakage protector, is an electrical safety device that detects and protects against electrical shock hazards caused by leakage current. When selecting an Earth Leakage Circuit Breaker (ELCB), it is crucial to consider factors such as Ampere frame, Number of Poles, Rate Current, Rate Operating, Voltage, Mounting Method (e.g., DIN rail mount, Fasten with screws, and etc.), and Size (height , width and depth). These considerations are vital for ensuring the production of high-quality products. We highly recommend reputable brands like MITSUBISHI , FUJI ELECTRIC , and NITTO KOGYO
Take advantage of the convenience of FREE SHIPPING and NO MINIMUM ORDER on the Earth Leakage Circuit Breaker (ELCB). If you have any doubts or require assistance in choosing the right product, our experts are readily available to provide advice and guidance.
CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less

3 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    EBS series (distribution-panel type leak breaker) [EBS32FB]

    EBS series (distribution-panel type leak breaker) [EBS32FB]

    LSIS

    [Features]
    · Small space-saving leakage breaker for distribution board.
    · The distribution board type is compact and can be used for distribution boards.
    · Substantial lineup of rated current from 5 A to 100A.
    · Height 96 mm, depth 60 mm, JIS agreement size.
    · Easy attachment of auxiliary equipment.
    · Passed testing, CE mark certified product.
    · Types with a breaking capacity of 5kA or 10kA are available.

    Ampere frame AF Rated block capacity AC 200 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    30AF or less / 50AF / 100AF to 199AF 5 ~ 10 2 / 3 100 to 220 5 ~ 100 30 ~ 100 DIN rail mount PSE 96 50 ~ 75 80 Available Surface type
    From: ₹ 5,128.57
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    EBS [N]□□C series (high breaking capacity type leakage breaker) [EBS53C]

    EBS [N]□□C series (high breaking capacity type leakage breaker) [EBS53C]

    LSIS

    [Features]
    · PSE compatible leakage breaker with high reliable performance.
    · The rated cutoff capacity is as high as 35kA providing great relief.
    · Rated current 15A to 100A enriches our lineup.
    · Easy attachment of auxiliary equipment.
    · It is a product compatible with CE marking through certification testing.

    Ampere frame AF Rated block capacity AC 200 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    50AF / 60AF / 100AF to 199AF 30 ~ 35 3 220 15 ~ 100 30 - PSE 130 75 60 Available Surface type
    From: ₹ 10,278.57
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Earth Leakage Circuit Breaker (Conventional Type), GE-C

    Earth Leakage Circuit Breaker (Conventional Type), GE-C

    NITTO KOGYO

    This is an earth leakage circuit breaker (JIS-compliant type) that also serves as motor protection. It is compatible with lightning surge and harmonic.

    Ampere frame AF Rated block capacity AC 200 V(kA) Number of Poles Rated Operating Voltage(V) Rated Current(A) rate sensitivity current(mA) Mounting Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Connection Method
    50AF - 3 For both AC 100-200 - - Fasten With Screws PSE 98 - - Available -
    From: ₹ 7,851.40
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
Brand
Product Series
From
Days to Ship
Ampere frame AF
Rated block capacity AC 200 V(kA)
Number of Poles
Rated Operating Voltage(V)
Rated Current(A)
rate sensitivity current(mA)
Mounting Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Connection Method

    You can add up to 6 items per a category to the compare list.

    EBS series (distribution-panel type leak breaker) [EBS32FB]

        You can add up to 6 items per a category to the compare list.

        EBS [N]□□C series (high breaking capacity type leakage breaker) [EBS53C]

            You can add up to 6 items per a category to the compare list.

            Earth Leakage Circuit Breaker (Conventional Type), GE-C
              Brand

              LSIS

              LSIS

              NITTO KOGYO

              Product Series

              EBS series (distribution-panel type leak breaker) [EBS32FB]

              EBS [N]□□C series (high breaking capacity type leakage breaker) [EBS53C]

              Earth Leakage Circuit Breaker (Conventional Type), GE-C

              From

              ₹ 5,128.57

              ₹ 10,278.57

              ₹ 7,851.40

              Days to Ship 5 Day(s) or more 5 Day(s) or more 6 Day(s) or more
              Ampere frame AF30AF or less / 50AF / 100AF to 199AF50AF / 60AF / 100AF to 199AF50AF
              Rated block capacity AC 200 V(kA)5 ~ 1030 ~ 35-
              Number of Poles2 / 333
              Rated Operating Voltage(V)100 to 220220For both AC 100-200
              Rated Current(A)5 ~ 10015 ~ 100-
              rate sensitivity current(mA)30 ~ 10030-
              Mounting MethodDIN rail mount-Fasten With Screws
              Representative StandardPSEPSEPSE
              Dimension height(mm)9613098
              Dimension width(mm)50 ~ 7575-
              Dimension depth(mm)8060-
              Rated block capacity, voltages except VAC 100/200/400, VDC 250AvailableAvailableAvailable
              Connection MethodSurface typeSurface type-

              Loading...

              1. 1

              Related Categories to Earth Leakage Breakers (Low Capacity)

              FAQ Earth Leakage Circuit Breakers (Low Capacity)

              Question: What is the function and capacity of an Earth Leakage Circuit Breaker (ELCB)?
              Answer: An Earth Leakage Circuit Breaker (ELCB) is a crucial safety device in electrical installations. Its primary function is to protect individuals from electric shock by automatically disconnecting the power supply when a fault occurs. ELCBs are designed to detect imbalances in the current flowing between live and neutral conductors. When a leakage current exceeds its rated value (typically 30mA or 100mA), the ELCB trips, interrupting the circuit and preventing potentially fatal injuries. This rapid response time ensures immediate protection against electric shock hazards.
              Question: What are the typical reasons for an Earth Leakage Circuit Breaker (ELCB) to trip, and how does one troubleshoot it?
              Answer: ELCB Tripping: Reasons and Troubleshooting
              Common Reasons:
              1.Earth Leakage: Current flows through unintended path (faulty appliance, wiring, water).
              2.Circuit Overload: Current exceeds ELCB's rating (too many appliances).
              3.Nuisance Trips: High sensitivity, electrical noise, power surges.
              4.Troubleshooting:

              Identify affected circuit and appliances.
              1.Turn off all appliances and reset ELCB.
              2.Switch on appliances one by one to find the culprit.
              3.Repair/replace faulty appliance or fix wiring.
              4.Test ELCB again with all appliances on.
              Question: How does one determine the appropriate tripping capacity and minimum rating for an Earth Leakage Circuit Breaker (ELCB)?
              Answer: 1. Tripping Capacity: This depends on potential fault currents and the maximum allowable leakage. Factors include:
              - Fault Current Loop Impedance: The resistance of the path the fault current takes to Earth, influencing how quickly the ELCB trips.
              - Maximum Earth Fault Current: The highest current the ELCB should allow to flow before tripping, typically 30mA or 100mA.

              2.Minimum Current Rating: This is based on the circuit's maximum current demand and needs to be equal to or higher than the expected circuit load. Factors include:
              - Circuit Load: The total current drawn by all appliances connected to the circuit.
              - Diversity Factor: Considers that all appliances won't operate at maximum load simultaneously.
              Question: What are the standard sizes of earth leakage, and how do you calculate the correct size for your needs?
              Answer: Earth leakage circuit breakers (ELCBs) come in a range of standard sizes, typically specified by their rated current (In) and tripping sensitivity (IΔn). Common sizes include:
              1.Current (In): 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A, 125A
              2.Sensitivity (IΔn): 30mA, 100mA, 300mA

              Choosing the correct size for your needs involves two main considerations:
              1.Maximum Current Demand: Calculate the total current drawn by all appliances connected to the circuit.
              2.Tripping Sensitivity: Based on safety requirements and potential fault scenarios.

              Example: Sum all appliance currents:
              Appliance A: 300W (1.3A)
              Appliance B: 500W (2.17A)
              Total current demand: 3.47A
              This means you need an ELCB with a rated current (In) equal to or greater than 3.47A.
              Question: How do you measure earth leakage current, and what is the acceptable range for safety standards?
              Answer: Measuring earth leakage current requires a specialized instrument called an earth leakage clamp meter. It clamps around the earth conductor of the circuit and measures the current flowing through it. Acceptable levels for safety vary depending on regulations and application:
              - IEC 60364-4-42: 30mA maximum for general residential installations.
              - BS 7671: 30mA for most domestic circuits, 100mA for specific situations (e.g., bathrooms).
              X
              whatsapp-qr whatsapp-icon