PLC (Wire-Saving Dedicated Units)(Additional Function:Analog I/O)

PLC (wire saving dedicated units) are units where connector terminal block conversion units are used for the connections with the PLC, which has many signals, in order to save wiring work and space. Many types are available, including those equipped with smart slave common functions and those where all wiring is performed with a single connector cable. Other types include low-profile waterproof types and spring clamp terminal block types, which can be used for connecting field network devices. PLC (wire saving dedicated units) include types that are very easy to mount without needing tools or soldering, but are still highly noise-resistant and reliable, and types that can be equipped with expansion units. Select according to the operating environment or application.
CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less

4 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Analog I/O slave CRT1

    Analog I/O slave CRT1

    OMRON

    Convert smart. Compute smartly. A simple and smart analog slave.
    [Features]
    ·In addition to inputting and outputting analog data, analog I/O slaves can process various operations inside the unit, such as scaling functions, which conventionally had to be processed on the ladder program of the host PLC.
    ·Analog processing similar to that of a digital panel meter is possible by using calculation functions such as the scaling function.
    ·By using the differentiation/integration function, it is possible to perform analog integration processing such as equipment abnormality prediction and diversion.
    ·By using the user calibration function, it is possible to correct the "deviation" of the input value (or output value).
    ·The input (or output) range can be easily changed by simply setting the switch.

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Slave station CompoNet Analog I/O Connector / Terminal block/connector DIN mount / Screw mount / DIN mount combination CE / UL / CUL / CSA
    From: ₹ 35,247.51
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    GX analog I/O terminal

    GX analog I/O terminal

    OMRON

    EtherCAT compatible analog I/O terminal with screw type terminal block.
    [Features]
    ·The input range (or output range) can be easily changed by simply setting the switch.
    ·Equipped with a detachable screw-type terminal block for improved maintainability.
    ·Equipped with a moving average calculation function. Configurable from 100µs to 64 ms (input only).
    ·Wire break detection function (input only, when used with 1-5 V, 4-20 mA).
    ·Rotary switch setting and tool setting can be selected for the node address.
    ·In the case of rotary switch settings, settings are easy, and node identification during maintenance is easy.

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Remote I/O station EtherCAT Analog I/O Terminal block/connector DIN mount CE / UL / CUL / CSA
    From: ₹ 44,995.20
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    DRT2 Analog Input/Output Terminal

    DRT2 Analog Input/Output Terminal

    OMRON

    DRT2 Analog Input/Output Terminal

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Slave station DeviceNet Analog I/O Connector DIN mount CE / UL / CUL / CSA
    From: ₹ 38,495.00
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Analog input/output unit GT1-AD / DA

    Analog input/output unit GT1-AD / DA

    OMRON

    Analog Input/Output Unit GT1-AD / DA

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Slave station DeviceNet Analog I/O Terminal Block / Connector DIN mount CE / UL / CSA
    From: ₹ 41,715.00
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
From
Days to Ship
Type
Control Type Network Varieties
Additional Function
Connection Terminal
Mounting Method
Representative Standard

    You can add up to 6 items per a category to the compare list.

    Analog I/O slave CRT1

        You can add up to 6 items per a category to the compare list.

        GX analog I/O terminal

            You can add up to 6 items per a category to the compare list.

            DRT2 Analog Input/Output Terminal

                You can add up to 6 items per a category to the compare list.

                Analog input/output unit GT1-AD / DA
                  Brand

                  OMRON

                  OMRON

                  OMRON

                  OMRON

                  Product Series

                  Analog I/O slave CRT1

                  GX analog I/O terminal

                  DRT2 Analog Input/Output Terminal

                  Analog input/output unit GT1-AD / DA

                  From

                  ₹ 35,247.51

                  ₹ 44,995.20

                  ₹ 38,495.00

                  ₹ 41,715.00

                  Days to Ship 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more
                  TypeSlave stationRemote I/O stationSlave stationSlave station
                  Control Type Network VarietiesCompoNetEtherCATDeviceNetDeviceNet
                  Additional FunctionAnalog I/OAnalog I/OAnalog I/OAnalog I/O
                  Connection TerminalConnector / Terminal block/connectorTerminal block/connectorConnectorTerminal Block / Connector
                  Mounting MethodDIN mount / Screw mount / DIN mount combinationDIN mountDIN mountDIN mount
                  Representative StandardCE / UL / CUL / CSACE / UL / CUL / CSACE / UL / CUL / CSACE / UL / CSA

                  Loading...

                  1. 1

                  Related Categories to PLC (Wire-Saving Dedicated Units)

                  FAQ PLC (Wire-Saving Dedicated Units)

                  Question: What are the unique features of PLC Wire-Saving Dedicated Units and how do they benefit industrial automation?
                  Answer: PLC Wire-Saving Dedicated Units offer streamlined connectivity by reducing the number of wires needed for communication. These units often employ advanced communication protocols and compact designs, minimizing wiring complexity. This not only simplifies installation but also enhances the overall reliability of the industrial automation system.
                  Question: How do Digital and Analog I/O Units integrate with PLC Wire-Saving systems?
                  Answer: Digital and Analog I/O Units seamlessly integrate with PLC Wire-Saving systems by connecting through a simplified wiring scheme. Digital I/O handles discrete signals, while Analog I/O manages continuous signals. Both types contribute to efficient data exchange between the PLC and various devices in the automation setup, supporting precise control and monitoring.
                  Question: What are the mounting and installation methods available for PLC Wire-Saving Dedicated Units?
                  Answer: PLC Wire-Saving Dedicated Units offer versatile mounting options, including DIN rail mounting for easy integration into control panels. Some units also support direct mounting on machines or equipment, providing flexibility in installation. This adaptability simplifies the deployment of these units in diverse industrial settings.
                  Question: What are the key considerations when selecting Analog I/O units for PLC systems?
                  Answer: When selecting Analog I/O units for PLC systems, key considerations include the required resolution, speed, and accuracy of the analog signals. Engineers should also evaluate compatibility with the PLC model, signal types supported (e.g., voltage or current), and the specific needs of the application. Additionally, considering factors like environmental conditions and electromagnetic interference ensures optimal performance in industrial settings.