(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
[Features]
· This product can be used to measure the thickness of a wide range of materials such as metal, glass, plastic, ceramic, epoxy, etc.
· This single unit covers a wide measurement range (0.8 to 300 mm) with a display resolution of 0.01 mm (display can be switched between 0.01 mm and 0.1 mm).
· Includes a scan mode to measure the smallest thickness detected within a wide range.
· 3 types of probes can be used to accommodate different applications.
· Thickness can be measured through a coating* (when using the AD-3255-04, sold separately).
· It is possible to measure the thickness of the object to be measured excluding the thickness of any paint or coating using echo/echo mode.
· Zero point adjustment of probes is supported. Includes 4 mm-equivalent test piece.
· Probes can be replaced.
· Supports sound speed adjustment.
· 1-point adjustment, 2-point adjustment and adjustment via numerical input are supported. Both setting and adjustment data are committed to the device's memory.
· Display of coupling state as well as verification of the contact state are supported.
· Remaining battery power can be displayed.
· When the batteries are exhausted, the battery indicator will flash.
· Equipped with battery-saving auto power off function.
· If the device is not used for approx. 5 minutes, the display will flash for 20 seconds and the power will turn off automatically.
· Backlight function allows easy viewing of values even in dark environments.
* Thickness measurement through a coating can be performed provided that the coating thickness is no greater than 1 mm and the ratio of the coating thickness to the thickness of the object being measured is at least 1:8.
· However, measurement may not be possible depending on the type of coating present and the state of the object being measured.
· Additionally, coating thickness can not be measured.
Part Number |
---|
AD-3255-04 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Measuring Range (μm) | Measurement accuracy | Display Resolution (mm) | Sound Speed Setting Range (m/s) | Display | Mass (g) | Measuring method | Unit of measurement | Power Supply | Battery life | Width (mm) | Depth (mm) | Height (mm) | Operating Frequency | Temperature Accuracy Guarantee Range (°C) | Accessory | Operating Temperature and Humidity Range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
₹ 38,945.49 | 1 Piece(s) | 6 Day(s) or more | Pulse/echo mode: 2 to 300.0, echo/echo mode: 4 to 30.0 | - | - | - | - | - | - | - | - | - | - | - | - | 5 MHz | - | - | - |
Loading...
Product Type | Film Thickness Gauge |
---|
Please check the type/dimensions/specifications of the part AD-3255-04 in the Ultrasonic Thickness Meter, AD-3255 Series series.
Part Number |
---|
AD-3255 |
AD-3255-01 |
AD-3255-02 |
AD-3255-03 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Measuring Range (μm) | Measurement accuracy | Display Resolution (mm) | Sound Speed Setting Range (m/s) | Display | Mass (g) | Measuring method | Unit of measurement | Power Supply | Battery life | Width (mm) | Depth (mm) | Height (mm) | Operating Frequency | Temperature Accuracy Guarantee Range (°C) | Accessory | Operating Temperature and Humidity Range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
₹ 103,834.11 | 1 Piece(s) | 6 Day(s) or more | 7 MHz probe: 0.8 to 200.0, 5 MHz probe: 1.0 to 300.0, 2.0 to 300.0, 4.0 to 30.0 (*measured over coating) | ±0.1 mm ±0.5% (measurement range: 0.8 to 50.0 mm), ±0.1 mm ±1.5% (measurement range: 50.1 to 300.0 mm) *Measurement and corresponding precision will depend on the state of the surface of the object being measured. | 0.01 mm / 0.1 mm selection supported (note that display resolution is 0.1 mm at 200.1 mm or greater) | 1,000 to 9,999 | 0.65 to 600.0 mm | Approx. 160 (dry cell batteries not included) | Ultrasonic pulse reflection method | mm | AA alkaline batteries × 2 | Continuous operation of 30 hours or longer (at 25°C, backlight off and 4 mm measurement) | 73 | 32 | 143 | - | 5 to 40 | 7 MHz probe, AD-3255-02 (standard probe) × 1 pc., 4 mm-equivalent test piece AD-3255-01 × 1 pc., carrying case × 1 pc., strap × 1 pc., empty bottle for contact medium × 1 pc., instruction manual × 1 pc. | 0 to 50°C, 85% RH or less (no condensation) | ||
₹ 6,088.65 | 1 Piece(s) | 5 Day(s) or more | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
₹ 29,279.56 | 1 Piece(s) | 6 Day(s) or more | Pulse/echo mode: 0.8 to 200.0 | - | - | - | - | - | - | - | - | - | - | - | - | 7 MHz | - | - | - | ||
₹ 29,279.56 | 1 Piece(s) | 6 Day(s) or more | Pulse/echo mode: 1.0 to 300.0 | - | - | - | - | - | - | - | - | - | - | - | - | 5 MHz | - | - | - |
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy