(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
Part Number |
---|
1-8968-01 |
1-8968-03 |
1-8968-05 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Cooling capability (W) |
External Dimensions (mm) |
Power Supply (V) |
Manufacturer Product Name | Manufacturer Model Number | Weight (kg) |
Power supply details | Power cord length (m) |
Maximum Operating Current (A) |
Liquid tank | Freezing machine | Internal Capacity |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
₹ 315,266.55 |
1 Piece(s) | 6 Day(s) or more | 1000 | 360×460×1020 | 100V | Thermostatic Water Circulation Device MTC-1000 | MTC-1000 | 55 | AC100V 50/60Hz | 2 (3P Plug + Adapter) | 8 | Stainless Steel: Approx. 16 L | 470W | 1 unit | ||
₹ 333,699.29 |
1 Piece(s) | 6 Day(s) or more | 1500 | 360×460×1020 | 100V | Thermostatic Water Circulation Device MTC-1500 | MTC-1500 | 60 | AC100V 50/60Hz | 2 (3P Plug + Adapter) | 9 | Stainless Steel: Approx. 16 L | 600W | 1 unit | ||
₹ 403,148.20 |
1 Piece(s) | 6 Day(s) or more | 3000 | 430×520×1110 | 200V | Thermostatic Water Circulation Device MTC-3000 | MTC-3000 | 80 | Single-Phase 200 VAC 50/60 Hz | 2 (Round Terminal) | 8 | Stainless Steel: Approx. 32 L | 900W | 1 unit |
Using a high-lift pump, circulation can be performed easily even if resistance at the destination of the circulation is high.
[Features]
· High-lift pump. (Maximum flow 40.7/44.6 L/min, max. pump head 13.6/19.1 m) used.
· Because it is set up with a bypass valve as a standard, the amount of flow can be adjusted.
· Equipped as standard with an external operation/external alarm output terminal and external alarm input terminal/remote control terminal.
· Operations can automatically be restarted, even after power outages, due to the power restoration function.
· Can also circulate pure water.
[Applications]
· A cooling device for semiconductor manufacturing devices.
Part Number |
---|
1-8968-01 |
1-8968-03 |
1-8968-05 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Cooling capability (W) |
External Dimensions (mm) |
Power Supply (V) |
Manufacturer Product Name | Manufacturer Model Number | Weight (kg) |
Power supply details | Power cord length (m) |
Maximum Operating Current (A) |
Liquid tank | Freezing machine | Internal Capacity |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
₹ 315,266.55 |
1 Piece(s) | 6 Day(s) or more | 1000 | 360×460×1020 | 100V | Thermostatic Water Circulation Device MTC-1000 | MTC-1000 | 55 | AC100V 50/60Hz | 2 (3P Plug + Adapter) | 8 | Stainless Steel: Approx. 16 L | 470W | 1 unit | ||
₹ 333,699.29 |
1 Piece(s) | 6 Day(s) or more | 1500 | 360×460×1020 | 100V | Thermostatic Water Circulation Device MTC-1500 | MTC-1500 | 60 | AC100V 50/60Hz | 2 (3P Plug + Adapter) | 9 | Stainless Steel: Approx. 16 L | 600W | 1 unit | ||
₹ 403,148.20 |
1 Piece(s) | 6 Day(s) or more | 3000 | 430×520×1110 | 200V | Thermostatic Water Circulation Device MTC-3000 | MTC-3000 | 80 | Single-Phase 200 VAC 50/60 Hz | 2 (Round Terminal) | 8 | Stainless Steel: Approx. 32 L | 900W | 1 unit |
Loading...
The product list can be filtered using the selections found beneath the specification item name.
Using a pump with a high pump head (max. flow rate 40.7/44.6 L/min and max. pump head 13.6/19.1 m) provides smooth circulation even to locations with significant resistance.
Comes standard with a bypass valve, allowing for general adjustment of flow rate.
Pure water can also be circulated, allowing it to also be used as a cooling device for semiconductor manufacturing equipment.
Comes standard with external operation / external alarm output terminal and external alarm input terminal / remote control terminal.
With a power outage recovery feature, it can be automatically restarted in the event of a power outage.
Back
Controller
Usage image
Circulation pump capacity graph (pump unit capacity)
Note) Values are not guaranteed.
Cooling time graph (50 Hz)
Note 1) Values are not guaranteed.
Note 2) Cooling performance will differ depending on conditions.
Cooling capacity graph (50 Hz)
Note 1) Values are not guaranteed.
Note 2) Cooling performance will differ depending on conditions.
Part No. | Model Number | Temperature Control Range (°C) | Cooling Performance (W) |
---|---|---|---|
1-8968-01 | MTC-1000 | 10 to 30 | 1,000 |
1-8968-03 | MTC-1500 | 10 to 30 | 1,500 |
1-8968-05 | MTC-3000 | 10 to 30 | 3,000 |
Model Number | MTC-1000 | MTC-1500 | MTC-3000 | |
---|---|---|---|---|
Circulation Method | Closed-System Circulation | |||
Performance | Cooling Performance | 1,000 W at Liquid Temperature 20℃ (Room Temperature 20℃) | 1,500 W at Liquid Temperature 20℃ (Room Temperature 20℃) | 3,000 W at Liquid Temperature 20℃ (Room Temperature 20℃) |
External Circulation Capacity (50/60 Hz) | Max. Flow Rate 40.7/44.6 L/min, Max. Pump Head 13.6/19.1 m (*Performance For Pump Unit) | |||
Functionality | Temperature Setting/Display | Sheet Key Input / Digital Display | ||
Safety Functions | Earth-Leakage Circuit Breaker, Freezer Overload, High-Voltage Pressure Switch, Circulation Pump Overcurrent Protection, Water Level Warning | |||
External Input/Output | External Alarm Output Terminal / External Operation Output Terminal / Remote Operation Terminal / External Alarm Input Terminal | |||
Components | Freezer | 470 W | 600 W | 900 W |
Refrigerant | R407C | |||
External Circulation Connection Port | Combined Discharge Outlet / Return Outlet, Outlet Diameter Rc3/4 | |||
Liquid Tank | Stainless Steel, Approx. 16 L | Stainless Steel, Approx. 32 L | ||
Electrical Characteristics | Power Supply | 100 V AC 50/60 Hz | Single-Phase 200 V AC 50/60 Hz | |
Power Cord Length | 2 m (3P Plug + Adapter) | 2 m (Round Terminal) | ||
Maximum Operating Current | 8 A | 9 A | 8 A | |
Outer Dimensions | 360 × 460 × 1,020 mm | 430 × 520 × 1,100 mm | ||
Weight | 55 kg | 60 kg | 80 kg |
* The performance is measured with room temperature at 20℃, 50 Hz and under no load.
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.