(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
For power supply switching at an impulse voltage of 10kV, and a withstand voltage of 4kV.
[Features]
· Fully separated between the input and output (between coil-contacts), providing 10,000V impulse withstand voltage.
· Features at least 8 mm insulation clearance between coil-contacts in compliance with VDE standard C/250. Has a withstand voltage of AC4,000V or higher in compliance with compliant with the Act on Product Safety of Electrical Appliances and Materials. Standard models are UL standard 508 and CSA standard certified.
· VDE certified products also available.
· The 1a type (TV-8) and 2a type (TV-5) both conform to TV ratings.
· Products with support for full-wave rectification also available.
Contact Configuration | 1a | 2a | ||
---|---|---|---|---|
Classification | Model | Coil Rated Voltage (V) | Model | Coil Rated Voltage (V) |
Standard Type | Model G4W-1112P-US-TV8 | 12 DC | Model G4W-2212P-US-TV5 | 12 DC |
24 DC | 24 DC |
G4W-2212P-US-TV5 external appearance
G4W Series dimensional outline drawing, Units: mm
PCB processing dimensions (G4W-1112P-US-TV8)
PCB processing dimensions (G4W-2112P-US-TV5)
The international (non-Japan) standard certification ratings are different from the performance values which were determined separately. As such, make sure you check these values before use.
Model | Number of Contacts | Operating Coil Rating | Contact Rating | Number of Times Tested |
---|---|---|---|---|
Model G4W-1112( )-US-TV8 | 1 | 12 to 100 V DC | 15 A 250 V AC (General Use) 40°C | 6,000 |
15 A 24 V DC 40°C | ||||
TV-8 40°C | 25,000 times | |||
1/2 HP 125 V AC 40°C | 1,000 times | |||
3/4 HP 240 V AC 40°C | ||||
1 HP 250 V AC 40°C | ||||
Model G4W-2212( )-US-TV5 | 2 | 15 A 250 V AC (General Use) 40°C | 6,000 | |
15 A 36 V DC 40°C | ||||
TV-5 40°C | 25,000 times | |||
1/4 HP 125 V AC 40°C | 1,000 times | |||
1/2 HP 250 V AC 40°C | ||||
1/3 HP 125 V AC 40°C | ||||
1/3 HP 250 V AC 40°C |
Model | Number of Contacts | Operating Coil Rating | Contact Rating | Number of Times Tested |
---|---|---|---|---|
Model G4W-1112( )-US-TV8 | 1 | 12 to 100 V DC | 15 A 250 V AC (General Use) 40°C | 6,000 |
15 A 24 V DC 40°C | ||||
TV-8 40°C | 25,000 times | |||
1/2 HP 125 V AC 40°C | 1,000 times | |||
3/4 HP 240 V AC 40°C | ||||
1 HP 250 V AC 40°C | ||||
Model G4W-2212( )-US-TV5 | 2 | 15 A 250 V AC (General Use, Same Polarity Between Contacts) 40°C | 6,000 | |
10 A 250 V AC (General Use) 40°C | ||||
15 A 24 V DC 40°C | ||||
TV-5 40℃ | 25,000 times | |||
1/2 HP 250 V AC 40°C | 1,000 times | |||
1/3 HP 125 V AC 40°C |
Items | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (W) | |
---|---|---|---|---|---|---|---|
Rated Voltage (V) | |||||||
DC | 12 | 66.7 | 180 | 80% or Less | 10% or More | 130% (at 23°C) | Approx. 0.8 W |
24 | 33.3 | 720 |
Type | 1a | 2a | ||
---|---|---|---|---|
Load | Resistance Load (cosφ = 1) | Inductive Load (cosφ = 0.4) | Resistance Load (cosφ = 1) | Inductive Load (cosφ = 0.4) |
Contact Material | Ag Alloy (Cd Free Material) | |||
Rated Load | 250 V AC 15 A 24 V DC 15 A | 250 V AC 10 A 24 V DC 7.5 A | 250 V AC 10 A 24 V DC 10 A | 250 V AC 7.5 A 24 V DC 5 A |
Rated Conduction Current | 15 A | 10 A | ||
Maximum Contact Voltage Value | 250 V AC, 125 V DC | |||
Maximum Contact Current Value | 15 A | 10 A | ||
Maximum Switching Capacity Value (Reference Values) | 3,750 VA 375 W | 2,500 VA 255 W | 2,500 VA 240 W | 1,850 VA 120 W |
Contact Resistance *1 | 30 mΩ or Less | |
---|---|---|
Turn-ON Time | 20 ms or Less | |
Turn-OFF Time | 5 ms or Less | |
Maximum Switching Frequency | Mechanical | 18,000 Times/h |
Rated Load | 1,800 Times/h | |
Insulation Resistance *2 | 100 MΩ or More | |
Withstand Voltage | Between Coil and Contact | 4,000 V AC 50/60 Hz 1 min |
Between Contacts of Same Polarity | 1,500 V AC 50/60 Hz 1 min | |
Between Contacts of Different Polarities (2a Type) | 2,000 V AC 50/60 Hz 1 min | |
Impulse Withstand Voltage | Between Coil and Contact | 10,000 V |
Insulation Distance | Between Coil and Contact | Space: 8 mm, Creepage: 8 mm |
Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm) |
Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm) | |
Shock / Impact | Durability | 1,000 m/s2 |
Malfunction | 150 m/s2 | |
Durability | Mechanical | 5,000,000 Times or More (Switching Frequency: 18,000 Times/h) |
Electrical | 100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h) | |
Failure Rate P Level (Reference Value *3) | 5 V DC, 100 mA | |
Ambient Operating Temperature | 25 to +55°C (Assuming No Freezing or Condensation) | |
Operating Ambient Humidity | 5 to 85% RH | |
Weight | Approx. 29 g |
Part Number |
---|
G4W-1112P-US-TV8 DC12 |
G4W-2212P-US-TV5 DC12 |
G4W-2212P-US-TV5 DC24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Contact Configuration | Contact rated current (minimum value for AC and DC) (A) | Coil rated voltage (DC) (V) | AC rated load |
---|---|---|---|---|---|---|---|---|
₹ 323.00 | 1 Piece(s) | Same day | 1a | 15 | 12 | AC250V 15A | ||
₹ 398.00 | 1 Piece(s) | Same day | 2a | 10 | 12 | AC250V 10A | ||
₹ 318.00 | 1 Piece(s) | Available | Same day | 2a | 10 | 24 | AC250V 10A |
Loading...
Application | Power | Terminal shape | For Circuit Boards | Dimension height(mm) | 30.5 |
---|---|---|---|---|---|
Dimension width(mm) | 30.5 | Dimension depth(mm) | 19.5 | Type | Standard Form |
Classification | Standard Type | Contact mechanism | Single |