[Features]
· An ultra-small two-pole slim relay.
· Supports high-density mounting (width: 5.7 mm × length: 10.6 mm × height: 9 mm).
· Features a high withstand voltage between coil-contacts of AC1,500V. Also has an impulse withstand voltage of 2.5kV2 × 10 μs (supports Telcordia standards).
· FCCpart68 (1,5kV10, 10 × 160 μs) compliant for between coil-contacts and between identical polarity contacts.
· The series also includes single coiled wire latching types, supporting power saving measures.
· The standard type is UL and CSA standard certified.
G6J-2P-Y external appearance
G6J-2P-Y dimensional outline drawing
PCB processing dimensions
UL/C-UL standards certified type (File No. E41515)
Number of Contacts | Operating Coil Rating | Contact Rating | Number of Times Tested |
---|---|---|---|
2c | Model G6J-2P-Y | 1 A 30 V DC 40°C 0.5 A 60 V DC 40°C 0.3 A 125 V AC 40°C | 6,000 |
Operating Coil/Single Stable Type (G6J-2P-Y)
Items | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
---|---|---|---|---|---|---|---|
Rated Voltage (V) | |||||||
DC | 5 | 28.9 | 173.1 | 75% or Less | 10% or More | 150% | Approx. 140 |
12 | 12.3 | 976.8 | |||||
24 | 9.2 | 2,600.5 | Approx. 230 |
*1: The rated current and coil resistance are measured at a coil temperature of 23°C and a tolerance of ±10%.
Note 2: The operating characteristics are measured at a coil temperature of +3°C.
*3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Load | Resistance Load |
---|---|
Rated Load | 125 V AC 0.3 A 30 V DC 1 A |
Rated Conduction Current | 1 A |
Maximum Contact Voltage Value | 125 V AC, 110 V DC |
Maximum Contact Current Value | 1 A |
Type | Single Stable Type | |
---|---|---|
Model | Model G6J-2P-Y | |
Contact Resistance *1 | 100 mΩ or Less | |
Operation (Set) Time *2 | 3 ms or Less (Approx. 1.6 ms) | |
Recovery (Reset) Time *2 | 3 ms or Less (Approx. 1.0 ms) | |
Minimum Set/Reset Pulse Width | - | |
Insulation Resistance *3 | 1,000 MΩ or More (at 500 V DC) | |
Withstand Voltage | Between Coil and Contact | 1,500 V AC 50/60 Hz 1 min |
Between Contacts of Different Polarities | 1,000 V AC 50/60 Hz 1 min | |
Between Contacts of Same Polarity | 750 V AC 50/60 Hz 1 min | |
Impulse Withstand Voltage | Between Coil and Contact | 2,500 V 2 × 10 μs |
Between Contacts of Different Polarities | 1,500 V 10 × 160 μs | |
Between Contacts of Same Polarity | ||
Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 2.5 mm (Double Amplitude 5 mm) |
Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) | |
Shock / Impact | Durability | 1,000 m/s2 |
Malfunction | 750 m/s2 | |
Durability | Mechanical | 50,000,000 Times or More (Switching Frequency: 36,000 Times/h) |
Electrical | 100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h) | |
Failure Rate P Level (Reference Value *4) | DC 10 mV 10 μA | |
Ambient Operating Temperature | -40 to +85°C (Assuming No Freezing or Condensation) | |
Operating Ambient Humidity | 5 to 85%RH | |
Weight | Approx. 1.0 g |
*The above values are the initial default values.
*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
*4. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.
Part Number |
---|
G6J-2P-Y DC12 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Coil rated voltage (DC) (V) |
---|---|---|---|---|---|
₹ 317.00 | 1 Piece(s) | Same day | 12 |
Loading...
Application | For Signals | Contact Configuration | 2c | Latch function | NA |
---|---|---|---|---|---|
Terminal shape | For Circuit Boards | Contact rated current (minimum value for AC and DC)(A) | 0.3 | Dimension height(mm) | 10 |
Dimension width(mm) | 10.6 | Dimension depth(mm) | 5.7 | Classification | Single stable shape |
Protective Structure | Plastic seal type | Contact mechanism | Crossbar twin | Circuit Board Mounting | Circuit Board Hole Insertion |
AC rated load(V)/(A) | AC125/0.3 | DC rated load(V)/(A) | DC30/1 |
Please check the type/dimensions/specifications of the part G6J-2P-Y DC12 in the Surface-mount Relay - G6J-Y series.
Part Number |
---|
G6J-2P-Y DC24 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Coil rated voltage (DC) (V) |
---|---|---|---|---|---|
₹ 375.00 | 1 Piece(s) |
Same day
Stock | 24 |
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy