(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
• ADA750F Series Model 750W Single Output AC-DC Power Supplies Enclosed Type.
• Compliant standard UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-AN.
• Input Frequency: 50/60 (47-63) or DC.
• Power output only 1 output power level is 750 Watt.
• Output voltage are DC (Direct current), 4 output voltage levels 24, 30, 36 and DC48V.
• Input voltage are DC (Direct current) and AC (Alternating current) AC85 - 264V.
(1 phase) or DC120 - 350V.
• Protection Circuit: Overcurrent and Overvoltage protection.
• OPERATING INDICATION: LED (Green color).
• Cooling method that is convection cooling or forced air.
Product picture of ADA750F model
Ordering information
- | Model | ADA750F-24 | ADA750F-30 | ADA750F-36 | ADA750F-48 | |
---|---|---|---|---|---|---|
INPUT | Voltage (V) | AC85 - 264 1 ⌀ or DC 120 - 350 (AC64 or DC90 optionally available *6) | ||||
Frequency (Hz) | 50/60 (47 - 63) or DC | |||||
Efficiency (%) | ACIN 100V | 86typ (lo=100%) | 86typ (lo=100%) | 87typ (lo=100%) | 87typ (lo=100%) | |
ACIN 200V | 88typ (lo=100%) | 88typ (lo=100%) | 89typ (lo=100%) | 89typ (lo=100%) | ||
Power Factor | ACIN 100V | 0.99typ (lo=100%) | ||||
ACIN 200V | 0.98typ (lo=100%) | |||||
Inrush Current (A) | ACIN 100V | 20typ (lo=100%) (More than 3sec.to re-start) | ||||
ACIN 200V | 40typ (lo=100%) (More than 3sec.to re-start) | |||||
Leakage Current (mA) | 0.75max (60Hz, According to IEC60950 and DE N-A N) (lo=100%) | |||||
OUTPUT | Voltage (V) | 24 | 30 | 36 | 48 | |
Current (A) | ACIN 100V | 17 (Peak 42) convection | 13.5 (Peak 33.5) convection | 11 (Peak 28) convection | 8 (Peak 21) convection | |
ACIN 100V | 25 (Peak 42) forced air | 20 (Peak 33.5) forced air | 16.5 (Peak 28) forced air | 12.5 (Peak 21) forced air | ||
ACIN 200V | 19 (Peak 63) convection | 15 (Peak 50) convection | 12.5 (Peak 42) convection | 9 (Peak 31.5) convection | ||
ACIN 200V | 31.5 (Peak 63) forced air | 24.5 (Peak 50) forced air | 20.5 (Peak 42) forced air | 15.5 (Peak 31.5) forced air | ||
Line Regulation (mV) | 96max | 120max | 144max | 192max | ||
Load Regulation (mV) | 150max | 180max | 240max | 300max | ||
Ripple (mVp-p) | 0 to +50 °C | 120max | 160max | 200max | 200max | |
-10 to 0 °C | 160max | 230max | 260max | 300max | ||
Ripple Noise (mVp-p) | 0 to +50 °C | 150max | 190max | 230max | 250max | |
-10 to 0 °C | 180max | 250max | 280max | 400max | ||
Tempearature Regulation (mv) | 0 to +50 °C | 240max | 300max | 360max | 480max | |
Drift (mV) | 96max | 120max | 144max | 192max | ||
Start-up Time (ms) | 500max (ACIN 100V, lo= 100%) | |||||
Hold-up Time (ms) | 20typ (ACIN 100V, lo= 100%) | |||||
Output Voltage Adjustment Range (V) | 21.6-27.0 | 27.0-33.0 | 33.0-41.0 | 24.0-52.8 | ||
Output Voltage Setting (V) | 23.5-24.5 | 29.0-31.0 | 35.0-37.0 | 47.0-49.0 | ||
PROTECTION CIRCUIT AND OTHERS | Overcurrent Protection | Work over 101% of peak current and recovers automatically | ||||
Overvoltage Protection | 31 - 34.5 | 40 - 48 | 51 - 60 | 64 - 76 | ||
Operating Indication | LED (Green) | |||||
Alarm Output | Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5) | |||||
Remote ON/OFF (RC) | Requirement for external source (Option : -R, refer to Instruction Manual 5) | |||||
ISOLATION | input-Ouput - RC | AC3,000V 1 minute, Cutoff current = 10mA, DC500V 50MΩ min (At Room Temperature) | ||||
Input - FC | AC2,000V 1 minute, Cutoff current = 10mA, DC500V 50MΩ min (At Room Temperature) | |||||
Output RC-FC | AC500V 1 minute, Cutoff current = 100mA, DC500V 50MΩ min (At Room Temperature) | |||||
ENVIRONMENT | Operating Tem., Humid. and Altitude | -10 to +71 °C , 20 - 90%RH ( Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max | ||||
Storage Temp., Humid. And Altitude | -20 to + 75 °C, 20 - 90%RH ( Non condensing), 9,000m (30,000feet) max | |||||
Vibration | 10 - 55Hz, 19.6m/s2 (2G), 3 minutes period, 60minutes each along X, Y and Z axis | |||||
Impact | 196.1 m/s2 (20G), 11 ms, once each X, Y and Z axis | |||||
SAFETY AND NOISE REGULATION | Agency Approvals | UL60950-1, C-UL(CSA60950-1 ), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input) | ||||
Conducted Noise | Complies with FCC-B, C1SPR22-B, EN55022-B, VCCI-B | |||||
Harmonic Attenuator | Complies with IEC61000-3-2 | |||||
OTHERS | Case Size/Weight | 70 X 127 X 230mm (2.76 X 5 X 9.06 inches) (W X H XD) (without terminal block) 11.9kg max | ||||
Cooling Method | Convection/Forced air |
Part Number |
---|
ADA750F-24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | RoHS |
---|---|---|---|---|---|
₹ 27,800.85 | 1 Piece(s) | 5 Day(s) or more | 10 |
Loading...
Shape | With Cover | Output power(W) | 750 | Single/multi | Single |
---|---|---|---|---|---|
Input Voltage | AC/DC | Output voltage (Single only) | DC24V | Rated output current (single only)(A) | 31.5 |
Input/output terminal shape | Terminal Block | Included Function | Parallel | Safety standards | CE / UL / CUL / TUV / CSA |
Height(mm) | 127 | Width(mm) | 70 | Depth(mm) | 230 |
Input Voltage(V) | AC85 to 264/DC120 to 350 | Voltage settings reliability(V) | 23.5 to 24.5 | Excess current protective circuit | Available |
Excess voltage protective circuit | Available | Output voltage variation(V) | 21.6 to 27 | Other optional functions | NA |
Peak current(A) | 63A (AC input 200 V) |
Please check the type/dimensions/specifications of the part ADA750F-24 in the ADA750F Model 750W Single Output series.
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy