(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

ADA750F Model 750W Single Output

ADA750F Model 750W Single Output
You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      27,801₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

Product Description

• ADA750F Series Model 750W Single Output AC-DC Power Supplies Enclosed Type.
• Compliant standard UL60950-1, C-UL(CSA60950-1), EN62368-1 Complies with DEN-AN.
• Input Frequency: 50/60 (47-63) or DC.
• Power output only 1 output power level is 750 Watt.
• Output voltage are DC (Direct current), 4 output voltage levels 24, 30, 36 and DC48V.
• Input voltage are DC (Direct current) and AC (Alternating current) AC85 - 264V.
(1 phase) or DC120 - 350V.
• Protection Circuit: Overcurrent and Overvoltage protection.
• OPERATING INDICATION: LED (Green color).
• Cooling method that is convection cooling or forced air.

ADA750F Model 750W Single Output

ADA750F Model 750W Single Output

Product picture of ADA750F model

ADA750F Model 750W Single Output

Ordering information

1. Series name
2. Output wattage
3. Universal input
4. Output voltage
Optional
G : Low leakage current
E : Low leakage current and EMI class A
F : With Fan unit
T : Vertical terminal block
J : Connector type
C : With Coating
R : Remote ON/OFF
N1: DIN rail
W: Alarms and Redundant operation
Specification is changed at option, refer to Instruction Manual.

Specifications

-ModelADA750F-24ADA750F-30ADA750F-36ADA750F-48
INPUTVoltage (V)AC85 - 264 1  or DC 120 - 350 (AC64 or DC90 optionally available *6)
Frequency (Hz)50/60 (47 - 63) or DC
Efficiency (%)ACIN 100V86typ (lo=100%)86typ (lo=100%)87typ (lo=100%)87typ (lo=100%)
ACIN 200V88typ (lo=100%)88typ (lo=100%)89typ (lo=100%)89typ (lo=100%)
Power FactorACIN 100V0.99typ (lo=100%)
ACIN 200V0.98typ (lo=100%)
Inrush Current (A)ACIN 100V20typ (lo=100%) (More than 3sec.to re-start)
ACIN 200V40typ (lo=100%) (More than 3sec.to re-start)
Leakage Current (mA)0.75max (60Hz, According to IEC60950 and DE N-A N) (lo=100%)
OUTPUTVoltage (V)24303648
Current (A)ACIN 100V17 (Peak 42) convection13.5 (Peak 33.5) convection11 (Peak 28) convection8 (Peak 21) convection
ACIN 100V25 (Peak 42) forced air20 (Peak 33.5) forced air16.5 (Peak 28) forced air12.5 (Peak 21) forced air
ACIN 200V19 (Peak 63) convection15 (Peak 50) convection12.5 (Peak 42) convection9 (Peak 31.5) convection
ACIN 200V31.5 (Peak 63) forced air24.5 (Peak 50) forced air20.5 (Peak 42) forced air15.5 (Peak 31.5) forced air
Line Regulation (mV)96max120max144max192max
Load Regulation (mV)150max180max240max300max
Ripple (mVp-p)0 to +50 °C120max160max200max200max
-10 to 0 °C160max230max260max300max
Ripple Noise (mVp-p)0 to +50 °C150max190max230max250max
-10 to 0 °C180max250max280max400max
Tempearature Regulation (mv)0 to +50 °C240max300max360max480max
Drift (mV)96max120max144max192max
Start-up Time (ms)500max (ACIN 100V, lo= 100%)
Hold-up Time (ms)20typ (ACIN 100V, lo= 100%)
Output Voltage Adjustment Range (V)21.6-27.027.0-33.033.0-41.024.0-52.8
Output Voltage Setting (V)23.5-24.529.0-31.035.0-37.047.0-49.0
PROTECTION CIRCUIT
AND OTHERS
Overcurrent ProtectionWork over 101% of peak current and recovers  automatically
Overvoltage Protection31 - 34.540 - 48        51 - 60                                64 - 76
Operating IndicationLED (Green)
Alarm OutputDetecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5)
Remote ON/OFF (RC)Requirement for external source (Option : -R, refer to Instruction Manual 5)
ISOLATIONinput-Ouput - RCAC3,000V 1 minute, Cutoff current = 10mA, DC500V 50MΩ min (At Room Temperature)
Input - FCAC2,000V 1 minute, Cutoff current = 10mA, DC500V 50MΩ min (At Room Temperature)
Output RC-FCAC500V 1 minute, Cutoff current = 100mA, DC500V 50MΩ min (At Room Temperature)
ENVIRONMENTOperating Tem., Humid. and Altitude-10 to +71 °C , 20 - 90%RH ( Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
Storage Temp., Humid. And Altitude-20 to + 75 °C, 20 - 90%RH ( Non condensing), 9,000m (30,000feet) max
Vibration10 - 55Hz, 19.6m/s2 (2G), 3 minutes period, 60minutes each along X, Y and Z axis
Impact196.1 m/s2 (20G), 11 ms, once each X, Y and Z axis
SAFETY AND
NOISE REGULATION
Agency ApprovalsUL60950-1, C-UL(CSA60950-1 ), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Conducted NoiseComplies with FCC-B, C1SPR22-B, EN55022-B, VCCI-B
Harmonic AttenuatorComplies with IEC61000-3-2
OTHERSCase Size/Weight70 X 127 X 230mm (2.76 X 5 X 9.06 inches) (W X H XD) (without terminal block) 11.9kg max
Cooling MethodConvection/Forced air

Drawing

Block Diagram

ADA750F Model 750W Single Output

External View

ADA750F Model 750W Single Output
Part Number
ADA750F-24
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipRoHS

₹ 27,800.85

1 Piece(s) 5 Day(s) or more 10

Loading...

  1. 1
 

Basic Information

Shape With Cover Output power(W) 750 Single/multi Single
Input Voltage AC/DC Output voltage (Single only) DC24V Rated output current (single only)(A) 31.5
Input/output terminal shape Terminal Block Included Function Parallel Safety standards CE / UL / CUL / TUV / CSA
Height(mm) 127 Width(mm) 70 Depth(mm) 230
Input Voltage(V) AC85 to 264/DC120 to 350 Voltage settings reliability(V) 23.5 to 24.5 Excess current protective circuit Available
Excess voltage protective circuit Available Output voltage variation(V) 21.6 to 27 Other optional functions NA
Peak current(A) 63A (AC input 200 V)

Please check the type/dimensions/specifications of the part ADA750F-24 in the ADA750F Model 750W Single Output series.

X
whatsapp-qr whatsapp-icon