(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

KVC36SB UL Listed Shielded Cable (Part Number)

KVC36SB UL Listed Shielded Cable
You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      8,103₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

Product Description

[Features]
・ Noise resistance
・ Flexibility
· Oil resistance
・ UL, cUL standard cable
[Applications]
・ Wiring to the control circuit of the machine tool
・ Wiring in an oil environment
・ Wiring to the portion requiring noise resistance

Product features details

Certification

Certification of factory automation electronic equipment wiring cable KVC-36SB series shielded

Operating Temperature Range

When fixed: -40 to 80°C *
* If you use it at a temperature below 0°C, you should be careful about impact, flexure, vibration and so on.

Bending radius

When fixed: 4 times or more of the cable outer diameter is recommended

Compliant standard

UL AWM 2936/2576/2937/2935

Structural outline

Part NumberKVC-36SB
0.2 mm^20.3 mm^20.5 mm^2
ConductorTin plated soft stranded copper wireAnnealed copper assembly line
Insulator105°C heat resistant vinyl mixture
Conductor strandingTwisted pair
Pair strandStrands of twisted pair in circular formWire cores twisted into a circular shape
TapeTape wrap around cores
ShieldTin coated annealed copper braid
SheathOil and heat resistant vinyl (Black)

Technical information and design ideas

Technical data

Cable TypeUL/cUL
Compatible size2, 3 × 0.1 to 0.3 mm^24 to 64 × 0.1 to 0.3 mm^22 to 4 × 0.5 mm^25 to 60 × 0.5 mm^2
Rated Voltage150 V300 V
Rated temperature80°C
Test voltage1,500 V AC, 1 minute2,000 V AC, 1 minute
Flame RetardancyFT2VW-1, FT1
Compatible standardUL AWM style 2936
CSA C22.2 No.210
UL AWM style 2576
CSA C22.2 No.210
UL AWM style 2937
CSA C22.2 No.210
UL AWM style 2935
CSA C22.2 No.210

* Since the Electrical Appliances and Materials Safety Act of Japan does not apply to KVC-36SB, please use it for weak current collection circuits such as signal and communication circuits.

Standard table

ConductorInsulationNumber of conductorsSheath outer diameter
(approx. mm)
Approximate weight
(kg/km)
Electrical characteristics
Nominal cross-sectional areaOuter Diameter (Approx. mm)
〈Configuration〉
Outer Diameter (Approx. mm)Allowable current
(A)
Conductor resistance
20°C
(Ω/km)
Insulation resistance
20°C
(M Ω km)
0.2 mm^2
[25AWG]
0.54
[7/0.18]
1.052 (1P)3.9215113 or less50 or more
34.1244
4 (2P)5.7404
5 (2P+1)5.8454
6 (3P)5.9454
7 (3P+1)6.0503
8 (4P)6.4553
10 (5P)6.8653
12 (6P)7.5753
14 (7P)7.7803
15 (7P+1)7.8803
16 (8P)8.2903
20 (10P)9.01052
24 (12P)9.11152
30 (15P)10.01402
36 (18P)11.01602
40 (20P)11.51702
50 (25P)12.52052
60 (30P)14.02452
64 (32P)14.02552
0.3 mm^2
[23AWG]
0.7
[12/0.18]
1.32 (1P)4.628762.3 or less50 or more
34.8356
4 (2P)6.2506
5 (2P+1)6.4555
6 (3P)7.1705
7 (3P+1)7.2705
8 (4P)7.8855
10 (5P)8.51004
12 (6P)9.31154
14 (7P)9.41204
15 (7P+1)9.51254
16 (8P)10.01354
20 (10P)11.51704
24 (12P)12.01853
30 (15P)13.02153
36 (18P)14.02553
40 (20P)14.52753
50 (25P)15.53353
60 (30P)17.03852
64 (32P)17.54052
0.5 mm^2
[20AWG]
0.95
[22/0.18]
1.6525.6451034.3 or less50 or more
35.9509
46.3608
57.0807
67.7957
77.71007
88.21156
109.31406
129.61506
1410.01655
1510.51755
1610.51905
2012.02255
2411.52655
2513.02754
2613.02804
3013.53104
4015.54004
5017.04904
6018.05803

Product characteristics

Characteristic radar chart

■0.2, 0.3 mm^2
Characteristic radar chart 1 of factory automation electronic equipment wiring cable KVC-36SB series shielded
■0.5 mm^2
Characteristic radar chart 2 of factory automation electronic equipment wiring cable KVC-36SB series shielded

* The flame retardant level varies depending on the size. See "flame retardancy" in the technical data.

Allowable current

  • Allowable current value is the calculated value when the ambient temperature is 30°C and laying work of a single cable in the air, and it is not a guaranteed value.
  • Allowable ampacity cable at ambient temperature above 30°C is to be determined by multiplying the following current reduction factor by the values in the table.
  • The allowable current value is the value calculated by JCS0168, and it is not the guaranteed value.
    JCS0168: Japanese Cable Makers' Association Standard "calculation of allowable current for power cables of 33 kV or less"

Current reduction factor

Ambient temperature (°C)3035404550556065707580859095100
Current reduction factor1.000.970.930.890.860.820.770.730.680.630.580.520.450.360.26

Wire core identification

Wire core identification table

■0.2, 0.3 mm^2

Wire core identification of factory automation electronic equipment wiring cable KVC-36SB series shielded
 

■0.5 mm^2

No. of Wire CoresWire core identification method
12 cores or lessInsulator coloring method (black, white, red, green, yellow, brown, blue, ash, orange, purple, peach, young grass in that order)
13 cores or moreNumbering No. method (continuous display of 1, 2, 3, 4 on the surface of the white insulator)

Structural drawing

■Example: KVC-36SB 8 (4P) × 0.3 mm^2 (23AWG)

Structural drawing 1 of factory automation electronic equipment wiring cable KVC-36SB series shielded
 

■Example: KVC-36SB 12 × 0.5 mm^2 (20AWG)

Structural drawing 2 of factory automation electronic equipment wiring cable KVC-36SB series shielded
Part Number
KVC-36SB 16(8P)X0.5SQ-10
KVC-36SB 16(8P)X0.5SQ-20
KVC-36SB 16(8P)X0.5SQ-30
Part NumberPriceMinimum Order Qty.Volume DiscountDays to Ship

₹ 8,103.33

1 Piece(s) 7 Day(s) or more

₹ 15,804.84

1 Piece(s) 7 Day(s) or more

₹ 23,608.52

1 Piece(s) 7 Day(s) or more

Loading...

  1. 1
 
X
whatsapp-qr whatsapp-icon