Select part number to Order Now/ Add to Cart
Ideal DIN rail mounting type for a system that connects a touch panel / PLC and a temperature controller while maintaining the operability and high performance of the E5□C type series.
Added push-in Plus terminal block type lineup.
[Features]
・ A slim body that fits in a low profile control panel with a DIN rail mounting type with a depth of 85 mm and a width of 22.5 mm
・ Easy-to-replace terminal block attachment/detachment structure improves maintainability
・ In addition to the screw terminal block type, you can select from the push-in Plus terminal block type that reduces wiring man-hours
・ Push-in Plus terminal block type is a connector and does not require wiring of power supply / communication line (Maximum number of connected units: 16)
・ High-speed sampling 50 ms makes it suitable for high-speed heating apps
・ Easy connection with PLC by programless communication
·By using a communication conversion cable (sold separately) to connect to a computer, settings can be configured without power wiring. Easy to set up from CX-Thermo (sold separately)
・ Enhanced basic functions of auxiliary output (2 points maximum) and event input (1 point maximum)
・ Easy-to-read white PV display that makes it easy to check when starting up or when something is wrong even inside the panel (PV height: 8.5 mm)
Part Number |
---|
E5DC-QX2ASM-002 |
E5DC-QX2ASM-017 |
E5DC-QX2DSM-002 |
E5DC-QX2DSM-017 |
E5DC-RX2ASM-002 |
E5DC-RX2ASM-017 |
E5DC-RX2DSM-002 |
E5DC-RX2DSM-017 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Output Type | Failure Detecting Function | Power Supply Voltage (V) | Control Output 1 | Auxiliary output points | Event Input (Point) | Heater Breakage, SSR Fault Detection Capability |
---|---|---|---|---|---|---|---|---|---|---|---|
₹ 28,414.44 | 1 Piece(s) | 5 Day(s) or more | SSR Drive Output Voltage | Heater Breakage / SSR Breakdown | 100 to 240 VAC | Voltage output (for driving SSR) | 2 (one common) | None | 1 | ||
₹ 20,207.96 | 1 Piece(s) | 20 Day(s) or more | SSR Drive Output Voltage | Heater Breakage / SSR Breakdown | 100 to 240 VAC | Voltage output (for driving SSR) | 2 (one common) | 1 | 1 | ||
₹ 28,414.44 | 1 Piece(s) | 5 Day(s) or more | SSR Drive Output Voltage | Heater Breakage / SSR Breakdown | 24 VAC/DC | Voltage output (for driving SSR) | 2 (one common) | None | 1 | ||
₹ 20,207.96 | 1 Piece(s) | 12 Day(s) or more | SSR Drive Output Voltage | Heater Breakage / SSR Breakdown | 24 VAC/DC | Voltage output (for driving SSR) | 2 (one common) | 1 | 1 | ||
₹ 28,414.44 | 1 Piece(s) | 5 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 100 to 240 VAC | Relay Output | 2 (one common) | None | 1 | ||
₹ 20,207.96 | 1 Piece(s) | 23 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 100 to 240 VAC | Relay Output | 2 (one common) | 1 | 1 | ||
₹ 28,414.44 | 1 Piece(s) | 20 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 24 VAC/DC | Relay Output | 2 (one common) | None | 1 | ||
₹ 20,207.96 | 1 Piece(s) | 84 Day(s) or more | Relay contact | Heater Breakage / SSR Breakdown | 24 VAC/DC | Relay Output | 2 (one common) | 1 | 1 |
Loading...
Number of Control Points | 1 | Number of Input Points(pcs.) | 1 | Acquired Standards | UL / CSA / CE |
---|---|---|---|---|---|
Type | Temperature Controller / Controller | Control Output 2 | No |